Elucidation:1:+12V 2:-15V3:Vout 4:0V(GND)OFS:Zero adjustment GIN:Gain adjustment
1.Incorrect wiring may cause damage to the sensor. After the sensor is powered on, when the measured current passes through the arrow direction of the sensor, the in-phase voltage value can be measured at the output end.
2.The output amplitude of the sensor can be adjusted according to the user's needs.
3.Sensors with different rated input current and output voltage can be customized according to user requirements.
Electrical characteristics | ||||||||
Type | FS050EK1 | FS100EK1 | FS200EK1 | FS300EK1 | FS400EK1 | FS500EK1 | ||
lp | Primary nominal input current | 50 | 100 | 200 | 300 | 400 | 500 | A |
Ip | Measuring range ofprimary current | 0~±100 | 0~±200 | 0~±400 | 0~±600 | 0~±800 | 0~±1000 | A |
Vour | Nominal output voltage | 4±1% | V | |||||
Vo | Supply voltage | ±12~±15(±5%) | V | |||||
。 | Current consumption | V=±15V <25 | mA | |||||
V | Insulation voltage | 3kV RMS /50Hz/1 min between primary and secondary side circuits | ||||||
e | Linearity | <1 | %FS | |||||
V₀ | Offset voltage | TA=25℃ <±25 | mV | |||||
Vow | Residual voltage | Ip→0 <±25 | mV | |||||
Vor | Thermal drift of V0 | Ip=0 TA=-25~+85℃ <±1 | mV/℃ | |||||
Tr | Response time | ≤7 | μ s | |||||
f | Frequency bandwidth(-3dB) | DC~20 | kHz | |||||
TA | Ambient operating temperature | -40~+85 | ℃ | |||||
Ts | Ambient storage temperature | -40~+100 | ℃ | |||||
R | Load resistance | ≥10K | Q | |||||
m | Quality (approx) | 68 | g | |||||
Standard | GI/FS-0105 |
>
Classify | Title | Download |
---|
Leave your contacts and our engineers will help you to find the solution you are looking for.
Hi! Welcome back.
How are you doing?
Let’s talk! We’ll provide the perfect solution for you!
Shanghai Freesor Sensor Technology Co. ,Ltd. was founded in 2005 by a number of overseas returnees with rich experience. It is a high-tech enterprise integrating design, research and development, production and sales.
Sales Center Add: Room 1405-1, Building B, 333 Haiyang 1st Road, Pudong New Area, Shanghai
Factory Add:Building 4, Keland Smart Energy Industrial Park, Guangming District, Shenzhen, Guangdong Province, China.