Closed loop (magnetically) Hall current sensor

FSM500LFBH Closed loop (magnetically) Hall current sensor

The FSM500LFBH is a current sensor that applies the fluxgate principle to measure DC, AC, pulse and various irregular waveforms under galvanic isolation. The FSM500LFBH is characterized by high accuracy and linearity, high sensitivity and resolution, very low out-of-phase current and temperature drift. Widely used in instrumentation, medical equipment, metrology and calibration, laboratories, high-precision power supplies, new energy vehicles and so on.

Description

Advantages

Parameters

Selection

Download

电参数/Electrical characteristics


型号

Type

FSM500LFBH


IPN

原边额定输入电流

Primary nominal input current

±500

A

IP

原边电流测量范围

Measuring range ofprimary current                       

0±900

A

IOUT

副边额定输出电流

Nominal output current

±250

mA

KN

匝数比

turns ratio

1:2000


RM

测量电阻

measuring resistance

with±15V    @±500Amax          0(min)   34(max)

Ω

with±15V    @±900Amax          0(min)   10(max)

Ω

VC

电源电压

Supply voltage

±15(±5%)

V

IC

电流消耗

Current consumption

15+IP/KN

mA

VD

绝缘电压

Insulation voltage

在原边与副边电路之间5kV有效值/50Hz/1分钟

kV

X

线性度

Linearity

<0.005

%

εL

精度

accuracy

<0.02

%FS

IO

零点失调电流

Zero offset current

@TA=25℃                      3

uA

TC

失调电流温漂

Offset current temperature drift                            

@IPN=0  TA=-40+85℃          5

uA

di/dt

跟随精度

Follow accuracy

 

100

A/µs

TR

响应时间

Response time

@100A/μS,  10%-90%         1

μs

f

频带宽度(-3dB)

Band width (-3dB)

@-3dB                     DC100

kHz

TA

工作环境温度  

Operating ambient temperature                 

-40+85

TS

贮存环境温度

Storage ambient temperature                

-40+125

RS

副边线圈内阻

Internal resistance of secondary coil                     

@TA=25℃                      16

Ω

m

质量(约)

weigth(approx)

253

g

外形尺寸(mm/Dimensions of drawing(mm)

使用说明/Remarks

1.错误的接线可能导致传感器损坏。传感器通电后,当被测电流从传感器箭头方向穿过,即可在输出端测得同相电流值。

Incorrect wiring may result in damage to the sensor. After the sensor is energized, when the measured current passes through the sensor in the direction of the arrow, the same-phase current value can be measured at the output.

2.在正常工作情况下,有效指示灯处于常亮状态。如果指示灯熄灭,说明电流传感器处于非零磁通状态,如母线电流超过量程等。此时,传感器内部进入扫描状态,输出电流不再与输入电流信号等比例,一旦母线电流回落到量程之内,传感器即恢复正常工作。

Under normal operating conditions, the active indicator is in a constant state. If the indicator is off, it means that the current sensor is in a non-zero flux state, such as the bus current exceeds the range. At this time, the sensor internal scanning state, the output current is no longer proportional to the input current signal, once the bus current back down to within the range, the sensor is back to normal operation.

3.测量电阻是指测量直流电流时。若测量交流电流时,测量电阻降低到70%。R

Measuring resistance is when measuring DC current. If the measurement resistance is reduced to 70% when measuring AC current.

4.原边测量导线或铜棒温度不要超过100℃。

Do not exceed 100°C for the raw edge measuring lead or copper rod.


Classify Title Download

Need Any Help

Leave your contacts and our engineers will help you to find the solution you are looking for.